Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
Company Information | |||
[email protected] | |||
Mobile | +8613620394314 | ||
+8613620394314 | |||
13620394314 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
The HIMA F2 DO 16 02 is a safety-related controller module designed for safety-critical applications in industrial environments. This module is part of the F2 series of the HIMA Safety Instrumented Systems, which is recognized for providing high levels of safety in automation. The F2 DO 16 02 features 16 digital output channels that allow precise control of safety equipment, such as emergency shutdown systems, safety barriers, and process control equipment.
This 16-channel digital output module is designed to handle various industrial applications that require high reliability and functional safety. It offers advanced diagnostics, fault detection, and a compact design that meets the stringent requirements of functional safety standards such as SIL 3 as per IEC 61508 and IEC 61511. The HIMA F2 DO 16 02 is widely used in industries like oil and gas, chemical, petrochemical, and power generation, where safety is of the utmost importance.
Parameter | Specification |
---|---|
Dimensions (L x W x H) | 255 x 114 x 113 mm |
Weight | 2 kg |
Number of Channels | 16 Digital Outputs |
Input Voltage | 24 V DC |
Output Voltage | 24 V DC |
Power Consumption | 4W |
Response Time | 10 ms |
Certifications | SIL-3, IEC 61508, IEC 61511 |
Mounting | DIN Rail |
Operating Temperature | -40°C to +70°C |
Status Indicators | LED indicators for monitoring |
Isolation | Galvanic isolation |
Model | Description | Parameters |
---|---|---|
F2 DI 16 01 | 16-channel digital input module for F2 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.1 kg |
F2 AI 08 01 | 8-channel analog input module for F2 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.3 kg |
F2 AO 08 01 | 8-channel analog output module for F2 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.2 kg |
F2 IO 32 01 | 32-channel input/output module for F2 system | Dimensions: 255 x 114 x 113 mm, Weight: 3.0 kg |
F2 CPU 01 | Central processing unit for the F2 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.5 kg |
Model | Description | Parameters |
---|---|---|
F3 DO 16 02 | Digital output module for F3 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.0 kg |
F3 DI 16 01 | Digital input module for F3 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.0 kg |
F3 AI 08 01 | Analog input module for F3 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.5 kg |
F3 AO 08 01 | Analog output module for F3 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.4 kg |
F3 CPU 01 | Central processing unit for F3 system | Dimensions: 255 x 114 x 113 mm, Weight: 2.7 kg |
Q1: What is the primary function of the HIMA F2 DO 16 02 module?
A: The primary function of the F2 DO 16 02 is to provide 16 digital outputs for controlling safety-related equipment, ensuring operational safety and reliability in industrial environments.
Q2: In what industries can the F2 DO 16 02 be used?
A: The module is primarily used in oil and gas, chemical processing, petrochemical, and power generation industries, where safety is paramount.
Q3: What does SIL-3 certification mean for this module?
A: SIL-3 certification ensures that the F2 DO 16 02 module is capable of maintaining high integrity in safety-critical applications, reducing the risk of failure to an acceptable level.
Q4: How does the F2 DO 16 02 module communicate with other systems?
A: The module integrates seamlessly with other HIMA components and communicates via digital outputs to control safety equipment or trigger emergency shutdown processes.
Q5: Can the F2 DO 16 02 module be used in hazardous environments?
A: Yes, it is designed for use in hazardous environments where safety and operational reliability are critical.
Q6: What are the operating temperature ranges for the module?
A: The F2 DO 16 02 operates within a temperature range of -40°C to +70°C, making it suitable for extreme industrial conditions.
Q7: How is the module mounted?
A: The module can be mounted using DIN rail for easy integration into existing control systems.
Q8: What kind of diagnostics does the F2 DO 16 02 offer?
A: The module offers advanced diagnostics with continuous self-monitoring and LED status indicators, ensuring that any faults or failures are easily detected and addressed.
Q9: What is the power consumption of the F2 DO 16 02?
A: The module consumes 4W of power during operation, which makes it energy-efficient for safety-critical applications.
Q10: What is the warranty for the F2 DO 16 02?
A: The product comes with a 1-year warranty, ensuring peace of mind for customers with support options available for extended services.
Safeguard Your Critical Systems with Precision
The HIMA F2 DO 16 02 ensures high safety integrity and reliable control of safety-related systems, offering peace of mind in hazardous environments.
Maximize Operational Safety with HIMA's F2 Series
With the F2 DO 16 02, your industrial systems will operate with top-tier reliability, ensuring compliance with SIL-3 safety standards and reducing downtime.
16 Outputs, Unlimited Safety Assurance
The F2 DO 16 02 module offers 16 high-performance outputs for seamless control of your safety equipment, ensuring your systems are always protected.
Where Safety Meets Innovation
Choose the F2 DO 16 02 from HIMA to integrate cutting-edge safety features into your process control systems, enhancing operational safety and efficiency.