Our advantage
Global Logistics
We have a 10-year logistics and express cooperation agreement, so our products can be shipped to any place in the world.
Brand new and original
Our products are imported in bulk from the place of origin. Because of the cooperative relationship, our products are all original and 100% new.
24-hour service
We provide 7*24 hours service to our customers. We will be there whenever you need us.
Price advantage
All our products are priced very favorably because we have our own warehouse and supply.
Company Information | |||
[email protected] | |||
Mobile | +8613620394314 | ||
+8613620394314 | |||
13620394314 | |||
Add | Room 1004, No. 62 Xiangxiu Li, Siming District, Xiamen City, Fujian Province, China |
The HIMA F3349 is an 8-channel output module designed for safety-related applications. It is part of the HIMA safety system and provides SIL 3 (Safety Integrity Level 3) certified performance for critical, safety-sensitive processes. This module is engineered to provide high-reliability outputs, enabling safe control and shutdown in case of emergency situations, ensuring the safety and continuity of industrial operations.
The F3349 module is built to meet the stringent requirements of IEC 61508 and IEC 61511, making it ideal for industries like oil and gas, chemical processing, and nuclear power. Its compact design and fast response time make it a valuable addition to safety instrumented systems (SIS), emergency shutdown (ESD) systems, and turbine control systems.
Parameter | Specification |
---|---|
Model | F3349 |
Channels | 8 |
Output Type | Safety-related digital output |
Voltage | 24 VDC |
Output Current | 0.5 A per channel |
Response Time | < 1 ms |
Fault Tolerance | Redundant design with fault detection |
Certification | SIL 3 certified (IEC 61508, IEC 61511) |
Dimensions | 20 x 190 x 128 mm |
Weight | 0.16 kg |
Operating Temperature | -20°C to +60°C |
Humidity | 5% to 95% non-condensing |
Model | Description |
---|---|
HIMA F3331 | 8-channel safety-related output module. |
HIMA F3332 | 8-channel safety input module for redundancy. |
HIMA F3333 | 4-channel safety-related input module. |
HIMA F3334 | 4-channel output module with SIL 3 certification. |
HIMA F3340 | Analog input module with SIL 3 certification. |
Model | Description |
---|---|
HIMA F7121 | High-performance safety controller module. |
HIMA F7220 | Safety-related input/output module with fault tolerance. |
HIMA F7321 | High-speed analog output module for safety-critical applications. |
HIMA F7400 | Communication module for safe data exchange in industrial systems. |
HIMA F7405 | Safety communication interface for real-time systems. |
Q1: What is the HIMA F3349 used for?
A1: The HIMA F3349 is an 8-channel safety-related output module used to provide reliable outputs for safety-critical applications, ensuring safe control and emergency shutdown in industries like oil & gas, chemical plants, and nuclear power.
Q2: How many output channels does the HIMA F3349 have?
A2: The HIMA F3349 provides 8 output channels, enabling the control of multiple field devices simultaneously.
Q3: What certification does the HIMA F3349 have?
A3: The HIMA F3349 is SIL 3 certified according to IEC 61508 and IEC 61511, ensuring it meets the highest safety standards for critical processes.
Q4: What is the response time of the HIMA F3349?
A4: The HIMA F3349 has a response time of less than 1ms, allowing it to act quickly in emergency situations.
Q5: Is the HIMA F3349 suitable for use in hazardous environments?
A5: Yes, the HIMA F3349 is designed to operate in environments with temperatures ranging from -20°C to +60°C, making it suitable for harsh industrial conditions.
Q6: What is the form factor of the HIMA F3349?
A6: The module has a compact form factor of 20 x 190 x 128 mm and weighs just 0.16 kg, allowing easy integration into a wide variety of systems.
Q7: What industries can benefit from the HIMA F3349?
A7: The HIMA F3349 is ideal for industries that require high safety standards, such as oil & gas, chemical processing, nuclear power, and turbine control systems.
Q8: Can the HIMA F3349 handle faults?
A8: Yes, the HIMA F3349 features a redundant design, allowing the system to continue operating even if faults are detected, ensuring continuous safety in critical applications.
Q9: How reliable is the HIMA F3349?
A9: The HIMA F3349 is built to be highly reliable, providing continuous and fault-tolerant operation even in demanding and high-risk environments.
Q10: Can the HIMA F3349 be easily integrated into existing systems?
A10: Yes, the HIMA F3349 is designed for easy integration into existing HIMA safety systems, making it a flexible solution for various industrial applications.
Safety, Performance, and Reliability
The HIMA F3349 ensures top-tier SIL 3 certification and less than 1ms response time, providing reliable, fast outputs for safety-critical applications.
Compact Safety, Maximum Output
With its compact size of 20 x 190 x 128 mm and 8 channels of output, the HIMA F3349 delivers powerful performance in even the most space-constrained environments.
Redundant Design for Fault Tolerance
Designed for maximum reliability, the HIMA F3349 offers a redundant design that ensures continuous operation even when faults are present, making it perfect for high-risk applications.
Built to Perform in Harsh Environments
With an operational range of -20°C to +60°C, the HIMA F3349 is built to withstand the toughest industrial environments while ensuring safety and reliability.